A reading of 38 °C may be expected in a curing batch but unusual in a fresh batch when similar batches are already heating up. Temperature reflects two processes: microorganisms generate heat, while the material loses heat to the air and as water evaporates. A low reading may indicate reduced biological activity or high heat loss. Before choosing an intervention, establish where and when the reading was taken and under what conditions. [1, 2]

What to measure and what each indicator tells you

Table 1
IndicatorWhat it tells youWhat to check before drawing a conclusion
Material temperatureHow heating or cooling is progressing at the points monitored.Repeat at comparable locations and depths. Record ambient temperature and the time since the last turning, watering or change in aeration.
Material moistureHow much water the sample contains, expressed as a share of its wet mass.Inspect several zones. A composite sample may give an average but hide a waterlogged pocket. If you suspect a local problem, sample that area separately.
Pore-gas oxygenHow much oxygen remains in the gas at the sampling point.Check the probe and sampling line for leaks. Record whether the fan is on, which zone it serves and where you are in the cycle. A duct-gas reading does not replace a local measurement in the material.
Aeration system operationFan status, airflow by branch or differential pressure, depending on the instrumentation.Compare under the same settings. A running fan does not show that air is moving uniformly through the material. Check distribution as well as total airflow.
Odour, appearance and pHClues about feedstocks, waterlogged pockets, biological changes or emissions.Locate each observation and compare it with the recipe, recent rainfall and the activity under way. Record the pH method; do not compare readings from different methods directly.

Start with locations that can be marked on a batch sketch: for example, along the windrow and, where access is safe, at different depths. Keep some points for repeat measurements and add others around any anomaly. The number of points and frequency depend on geometry, process stage, variability and the purpose of the measurements. For an enclosed system, use only the designated access points and procedures; do not open or enter it to complete a set of readings. [1]

What a useful process log includes

Batch details: identifier, formation date, feedstock origins, recipe and masses, geometry or cell, and process stage. Reading: date and time, point and depth, instrument, value and unit, fan status and weather, plus the observation kept separate from the interpretation. Action: what changed, when, who was responsible and which follow-up reading will test the effect. Keep invalid readings in the log, clearly flagged with the reason, but exclude them from the trend calculation.

For example: “L-17, day 4, 08:00, point B, 0.7 m: 40 °C; pore-gas O₂ 4% by volume. Aeration has been running for 10 minutes. Material dense and wet at sampling point. Hypothesis: poor airflow through this zone. Check branch airflow and local moisture; repeat gas reading after checking the probe.” The temperature and oxygen readings are observations; the cause remains a hypothesis until checked. The figures are fictional and are not operating thresholds.

Local monitoring interface with a schematic view of the plant zones.
Source: Compost Systems Example of a local interface. The plant overview helps the operator identify the zone associated with a reading or status indication.
Online dashboard with cards showing temperature readings from several zones.
Source: Compost Systems Example of online monitoring across several zones. The displayed values illustrate the interface; they are not process targets.

Worked case: one zone stays cool even though the fan is running

Table 2
WhenPoint APoint BHow to use the information
Day 4, before intervention55 °C; O₂ 12% by volume40 °C; O₂ 4% by volumeRepeat at the same point in the aeration cycle and check the probe, then compare the material and aeration branches.
After checksLooser material; 52% moisture, wet basisDense material; 67% moisture, wet basisConfirm the difference with local samples. If airflow through the branches is comparable, mix preparation and water distribution are more plausible explanations than a general fan fault.
Next day, after restoring structure in the affected zone in line with the operating procedure56 °C; O₂ 12% by volume48 °C; O₂ 9% by volumeThe trend supports the intervention, but it does not prove a single cause. Repeat the readings and see whether the difference returns.

The example assumes comparable measurement points, a batch in the active phase and the same aeration settings. After remixing, the readings are taken in the same zone, not in precisely the same particles. Rising oxygen and narrowing temperature differences are useful signals, not evidence of successful sanitisation. At an actual facility, match the intervention to the likely cause: clear or repair a branch if there is no airflow; if the material is too dense and wet, restore structure with suitable material and address the source of excess water. Turning up the fan will not necessarily fix uneven distribution and may dry the zones that air already passes through readily. [1, 2]

Other signals need different checks

  • A fresh batch fails to warm anywhere. Check the instrument, batch age and size, the presence of slowly degradable material, moisture and oxygen before changing the recipe. Heat loss may dominate in a small batch.
  • Sharp, ammonia-like odour. Check the share of nitrogen-rich feedstocks, pH, temperature and aeration settings. Odour alone does not demonstrate an oxygen shortage, and pH should not be adjusted without a measurement.
  • Material is dry in only one zone. Compare areas near the air supply with the rest of the batch and check how irrigation water is distributed. Correct uneven distribution before increasing the dose across the entire batch.
  • Material reheats during storage. Check the curing history. If release depends on the finding, take a representative sample for an appropriate stability test. A low temperature on its own did not establish that the batch was stable. [2, 3]

When is an intervention confirmed?

Decide beforehand what result you expect and when it should be observable. Airflow restored by a branch repair can be checked immediately; a biological response should be followed over time at the same points under comparable conditions. If circumstances allow, change one factor at a time and record what stayed constant. Never delay mandatory safety or environmental actions just to keep the comparison clean. Use the applicable procedures and tests to validate sanitisation or release a finished batch; the troubleshooting log alone does not suffice.

See also moisture and dry matter, oxygen, porosity and aeration, temperature and sanitisation, compost stability, maturity and quality and odours and emissions.

References and further reading

  1. European Commission. Implementing Decision (EU) 2018/1147, BAT 36: key parameters in aerobic treatment and limitations on monitoring in enclosed systems; a technical reference in its own scope, not a monitoring plan for every facility
  2. FAO (Food and Agriculture Organization of the United Nations). On-farm composting methods, sections on process stages, aeration, moisture, windrow size and pH; agricultural context
  3. Oregon State University Extension. Interpreting compost analyses, “Compost maturity and stability”: biological stability and limits on interpreting tests
  4. International Compost Seminar 2026, Austria, 8 October (day 4). “4.1 Emissions and Their Treatment”, PDF pp. 13–16 and 19: parameters, windrow measurements and emissions monitoring. Organiser: Compost Systems GmbH. Pages consulted in the text extract.